used full time for specific research programmes by the external group, which has exclusive use of the beam. CRGs currently in operation Intrument name Instrument type Partners CRG Type D1B Powder diffractometer
Recherche
Recherche de beams.
400 résultats ont été trouvés en 3 millisecondes.
Affiche les résultats de 41 à 50 sur 400.
Pages
Pertinence: 19%
Pages
the 4-circle neutron diffractometer D8 . Participation in the building of the 4-circle and normal beam neutron diffractometer D15 . Co-responsible of 4-circle diffractometers D9 then D10 . Together with
Pertinence: 17%
Pages
understand protein behavior in solution. The probe used in SAS techniques can be an X-ray Beam (SAXS) or a Neutron beam (SANS). SAXS is very powerful for soluble protein but cannot distinguish between molecules ... detergent, while SANS can: using specific deuteration, the detergent can be made invisible to the neutron beam. In consequence, SANS is ...
Pertinence: 22%
Pages
of the neutron detector and of the cell fixture cross section in alignment to the incident neutron beam. The scintillator sits in the neutron detector head close to the cell fixture. The emitted scintillation ... ion light is reflected to the detector, which is orientated perpendicular to the incident neutron beam. Two heating cartridges inserted ...
Pertinence: 18%
Pages
primary white beam is reflected by a focussing monochromator made of 9 highly oriented pyrolytic graphite (HOPG) providing an important flux at the sample. The monochromator housing has two beam holes at take-off ... 85° and 115°, corresponding to 4.5 Å and 5.6 Å beams with HOPG and incorporates the slit systems and cooled Beryllium filter in a way ...
Pertinence: 26%
Pages
n geometry Transmission or backscattering Neutron beam Flux at sample position about 10 7 n/cm 2 /s Wavelength range 0.8 - 3.2 Å Sample stage-to-beam distance 40 - 70 mm Detector (1) (1) Photonics Science ... mm Geometry from transmission (γ=0º) to back scattering (γ=180º), preferred γ angles: 0º, 90º, 180º Beam divergence : about h= 0.6º, v= 0.8º ...
Pertinence: 27%
Pages
Guide hall, thermal beam H25 distance reactor-core to monochromator : 65 m Monochromator crystal d-spacing (Å) k i (Å -1 ) flux (10 7 cm -2 .s -1 ) PG(002) 3.355 2.662 3.5 4.10 6.0 Heusler(111) 3.435 2 ... α 0 = 12.λ (Å) α 1 , α 2 , α 3 = 10', 20', 30', 40', 60' adjustable by Soller collimators Sample beam size LxH=5 x 4 cm 2 Analyser PG(002) ...
Pertinence: 23%
Pages
Reactor hall, thermal beam H13 beam tube Ø 170 mm Monochromator crystal dhkl (Å ) ki (Å -1 ) flux (10 7 n.cm -2 s -1 ) Conditions polarised Heusler (111) (230x150mm 2 ) 3.437 2.662 4.1 8.0 1.05 7.0 0.55 ... vertical focusing 3 He detector 4 x 10 cm 2 (vertical) Beam cross-section 20 x 20 mm 2 Instrument Description IN20 is installed at the H13 ...
Pertinence: 29%
Pages
components of the beam conditioning part are the two background choppers, the double curvature mono-chromator with four faces and the Fermi chopper. The background choppers are rapidly pulsating beam shutters which ... Reactor hall, thermal beam H12 Monochromators PG 002: 2.20 ... 3.60 Å PG 004: 1.10 ... 1.80 Å Cu 220: 0.85 ... 1.50 Å Cu 111: 1.25 ...
Pertinence: 28%
Pages
Guide hall n° 1, thermal guide H24 beam cross section 30 x 75 mm 2 Monochromator crystal d -spacing in Å k i in Å -1 flux in 10 6 n cm -2 s -1 PG (002) 3.355 1.3 - 3.3 2.662 9.3 Cu (111) 2.087 2.0 - 5