Beam days lost per cycle on ILL & CRG instruments (≈1600 to 2600 days allocated per cycle) Beam days lost per cycle on ILL public instruments (+1000 days allocated per cycle)
Recherche
Recherche de beams.
399 résultats ont été trouvés en 2 millisecondes.
Affiche les résultats de 41 à 50 sur 399.
Pages
Pertinence: 28%
Pages
components of the beam conditioning part are the two background choppers, the double curvature mono-chromator with four faces and the Fermi chopper. The background choppers are rapidly pulsating beam shutters which ... Reactor hall, thermal beam H12 Monochromators PG 002: 2.20 ... 3.60 Å PG 004: 1.10 ... 1.80 Å Cu 220: 0.85 ... 1.50 Å Cu 111: 1.25 ...
Pertinence: 28%
Pages
multiple or higher-order Bragg scattering (polarising crystals). The beam polarisation obtained with an NSF is perfectly homogeneous over the beam profile and there is no γ-background created by the absorption ... field gradient: < 3. 10 -4 cm -1 Overall performance 85% polarisation in static mode 80% on neutron beam Production rate: 2.5 ...
Pertinence: 28%
Pages
fr is required for their reservation and preparation. Code Max. Pressure (GPa) Material in Beam Thickness in Beam Sample Dimensions Transmitter Cryostat 01PCL100TZ6 1 @ 300K TiZr 13 Ø6 x 20 Fluorinert Fc770 ... pressure in a press and then clamped using a locking nut before being transferred into the neutron beam (directly or inside a cryostat). ...
Pertinence: 28%
Pages
display values for estimations of the minimal and maximal distance (radius) of the scattered beam from the beam centre the corresponding values for the momentum transfer Q the corresponding values of the ... Complete the setting information by choosing the collimation, the beamstop position Bx and By, the beam centre values X0 and Y0 (in pixels) ...
Pertinence: 28%
Pages
monochromator using a single reflection via a highly oriented pyrolytic graphite (HOPG) crystal provides a beam at a fixed take-off angle with a wavelength of 2.4 Å. MoTo was designed for long experiments with ... contrast options to measure independently of NeXT. Access to the hutch is possible only when the NeXT beam is off, and needs to be ...
Pertinence: 28%
Pages
Instrument Data beam size at sample 40 x 10 mm 2 incident wavelength range 2 - 30 Å scattering plane vertical Figaro Time-of-flight 4 choppers Frame overlap mirrors [20Å] [30Å] white beam flux at sample ... sample ~10 8 n cm -2 s -1 angle undeflected beam 0.62˚ angles deflected beam -2.5˚ < θ < 3.8˚ (horizontal) constant wavelength resolution δλ/λ ...
Pertinence: 28%
Pages
n geometry Transmission or backscattering Neutron beam Flux at sample position about 10 7 n/cm 2 /s Wavelength range 0.8 - 3.2 Å Sample stage-to-beam distance 40 - 70 mm Detector (1) (1) Photonics Science ... mm Geometry from transmission (γ=0º) to back scattering (γ=180º), preferred γ angles: 0º, 90º, 180º Beam divergence : about h= 0.6º, v= 0.8º ...
Pertinence: 27%
Pages
prototype in December 2017 at the LLB on the G4.3 instrument. Two beam conditions were used: a narrow beam of 3 mm x 3mm, or a non collimated beam with a plexi attenuator to avoid signal saturation. The detection ... detection efficiency measured at 2.8 Å with the narrow beam centered in the middle of the cells was 51% with the standard grid, and ...
Pertinence: 27%
Pages
r is extremely simple. When a single crystal is placed in a white beam it diffracts neutrons in many directions. The diffracted beams which hit the detector surface produce so called Bragg dots of varying
Pertinence: 27%