A5 - AG3 Ø70 Top loading 106ILHV49 1.5 - 550 A5 - AG3 Ø49 x 112 Top loading 118ILHV49 1.5 - 550 A5 - AG3 Ø49 Dual-exchanger, top loading, compatible with Cryopad-III 119ILHV49 1.5 - 550 A5 - AG3 Ø49 Top ... loading, new cold-valve 141ILHV49 1.5 - 550 A5 - AG3 Ø49 x 110 Top loading 145ILHV70 1.5 - 550 A5 - AG3 Ø70 x 195 Top loading 155ILHV49 1.8 - ...
Recherche
Recherche de 3he.
60 résultats ont été trouvés en 6 millisecondes.
Affiche les résultats de 41 à 50 sur 60.
Pages
Pertinence: 14%
Pages
and testing of novel therapeutic approaches to systemic amyloidosis and Alzheimer’s disease. CH3NH3PbI3 hybrid halide perovskite: beyond photovoltaics Friday, 24 March 2017, at 2:00 p.m. Chadwick amphitheatre ... Lausanne CH-1015 Lausanne laszlo.forro@ remove-this. epfl.ch Recently, it has been shown that CH3NH3PbI3 is very promising material in ...
Pertinence: 9%
Events - From 04.09.26 to 04.09.26
Pertinence: 98%
Pages
used for College 6 proposals are: Reflectometers: SuperADAM , D17 Diffractometers: D1B , D2B , D20 , D3 , D4 , XTREMED SANS spectrometers: D11 , D22 , D33 Small momentum transfer diffractometer: D16 Triple-axis ... rs: IN15 , WASP If you want to come to the ILL and give a seminar, please contact Gabriel Cuello . He can schedule a seminar at the ILL ...
Pertinence: 15%
Pages
please contact the college secretary. He can schedule a seminar at the ILL any time (best on Monday and Wednesday). Travel and expenses for your stay may be reimbursed (3 per diems and travel support). Do
Pertinence: 14%
Pages
Monochromators PG 002: 2.20 ... 3.60 Å PG 004: 1.10 ... 1.80 Å Cu 220: 0.85 ... 1.50 Å Cu 111: 1.25 ... 2.24 Å take-off angle 2θM 39 ° ... 65° resolution δ> E i / E i 3 ... 6 % flux on sample 5 x 105 cm ... cm -2 s -1 background choppers ν max 5 000 rpm Fermi chopper ν max 32 000 rpm duty cycle 3 x 10 -3 beam size on sample 2 x 4 cm 2 primary ...
Pertinence: 42%
Pages
in 10 6 n cm -2 s -1 PG (002) 3.355 1.3 - 3.3 2.662 9.3 Cu (111) 2.087 2.0 - 5.3 2.662 3.6 Heusler (111) 3.452 1.3 - 3.2 2.662 2.0 Collimation α1 = (0.015/ki) rad/Å -1 α2, α3, α4 = 10', 20', 30', 40', 60' ... adjustable by soller collimators Analyser horizontally focussing PG(002) 3He detector 50 mm Ø x 12 cm Instrument description IN3 is a classic ...
Pertinence: 42%
Pages
05-0.8 Å -1 0.05-0.8 Å -1 0.05-0.5 Å -1 3% 2.9% 2.4% 0.02 49.9 meV 2 m 4 m 6 m ± 50 ± 45 ± 35 1° - 15° 1° - 15° 1° - 9° 0.09-1.3 Å -1 0.09-1.3 Å -1 0.09-0.8 Å -1 3.8% 3% 2.7% 0.03 83.6 meV 2 m 4 m 6 m ± 80 ... equipment Furnace: T=300-1500K Sample access diameter: 40mm Detectors PSD Reuter-Stockes 3He multi-tube assembly 100 3He filled (15 bar) ...
Pertinence: 20%
Pages
<210° +56° < χ <205° -180° < φ <180° Detector 120° x 30° position-sensitive detector detector gas: 3He (5 atm) + CF4 (1 atm) Nominal resolution for fixed sample-detector distance of 76 cm 0.19° horiz. x ... sample. The new very large banana PSD is of innovative design and works at high gas pressure (5 atm 3He + 1 atm CF 4 ) for high efficiency ...
Pertinence: 36%
Pages
9° x 0.9° Angular range 2° ... 120° Fourier time range 0.03 ... 50 ns (10 Å) 0.002 ... 3 ns (4 Å) Energy range 1.3x10 -5 ... 0.01 meV (10 Å) 2x10-4 ... 0.15 meV (4 Å) Momentum transfer range 0.03 ... 2 ... sample stage takes all ILL standard sample environments including orange cryostats, cryo-furnaces and 3He cryostats. A non-magnetic high ...
Pertinence: 17%