Example of RAW DATA DIRECTLY TRANSFORMED IN S(Q,w) ;(without any rebin or radial integration) ; 1) Get beam center and mask from transmission measurement w1=rdrun(24420) & w1=total(w1,3) c=brisp_center(W1,Rb_stop=8
Recherche
Recherche de beams.
121 résultats ont été trouvés en 4 millisecondes.
Affiche les résultats de 31 à 40 sur 121.
Pages
Pertinence: 67%
Pages
Simulated experiment The polychromatic beam from the hot neutron tube H3 arrives at the monochromator. The monochromatic diffracted beam reaches the sample – a single crystal - located at the centre of ... rotated step by step around the vertical axis while the detector records the intensity of the diffracted beam of the selected Bragg reflection. ...
Pertinence: 93%
Pages
with the 3He neutron spin filter During this first test of an 3 He neutron spin filter, the neutron-beam polarisation transmitted by the filter could be determined with high accuray from spin dichroism
Pertinence: 71%
Pages
and magnetization density maps (also in 3D and for non-orthogonal systems) supports 4-circle, normal-beam, minimum-tilt and cryocradle geometries correction of polarization data for 3He spin-filter cell ... after using the on-the-fly absorption and/or Becker-Coppens extinction correction (i.e. peak-specific beam path length calcuation) new ...
Pertinence: 26%
Pages
4-circle geometry. The polychromatic beam from the thermal neutron guide H24 arrives on the monochromator, which selects a given wavelength. The monochromatic beam passes through slits to limit its size ... planes diffract into the equatorial plane. The detector is rotated to the location of the diffracted beam, which is then scanned step by step. ...
Pertinence: 93%
Pages
orientation. The scattered beam, which may have a different wavelength from the incident beam, arrives on the analyser. To obtain the wavelength (or energy) of the scattered beam, a scan is performed by the ... scattering experiment. The polychromatic beam from the thermal neutron guide H24 arrives on the monochromator, which selects a given ...
Pertinence: 98%
Pages
but the descending portion shows the presence of oscillations resulting from interference between beams reflected by the two surfaces. The size of these oscillations is related to the layer thickness. The
Pertinence: 75%
Pages
distance distribution. To prove this, it is enough to deform a metal sample placed in an X-ray or neutron beam.
Pertinence: 75%
Pages
the principal challenges during strain experiments is the movement of the specimen about the neutron beam (gauge volume). SALSA uses a unique hexapod design which has significant advantages over traditional ... during an experiment. A 300mm diameter, 500mm long steel pipe section is maneuvered around the neutron beam for measurements of lattice ...
Pertinence: 88%
Pages
Simulated experiment The white beam (polychromatic) from the thermal tube H11 arrives at the monochromator. Monochromatic diffracted beams reache the sample – a single crystal - located at the centre of ... Eulerian cradle. The curved two-dimensional position-sensitive detector (PSD) records all diffracted beams within its angular range (120° × ...
Pertinence: 96%
