cradles for orienting the sample crystals, with the detector moving in a horizontal plane. Normal-beam diffractometers have a mechanism for tilting the counter out of the horizontal plane, thus enabling
Recherche
Recherche de beams.
388 résultats ont été trouvés en 9 millisecondes.
Affiche les résultats de 11 à 20 sur 388.
Pages
Pertinence: 11%
Pages
development of microfluidics and small sample volume measurements. The new options on D22 with white beam and increased wavelength spread (by tilting the selector) give more flux that benefit fast kinetic ... instrument combining most of the possible options for SANS: conventional SANS mode with monochromatic beam by using a velocity selector; TOF ...
Pertinence: 12%
Pages
into 'Trans Empty 1': '28068' Empty Beam Transmission into 'Trans Empty Beam 1': '28064' Empty Beam intensities for the three instrument configurations into 'I0 Beam Intensity 1': 28051, 28064, 28084' All ... relative to that of the empty beam. Calculate Beam Centres Toggle the 'Foreground & Data Load' selector to display the 'I0 Beam Intensity 1' ...
Pertinence: 29%
Pages
ry have been possible recently thanks to the possibility to strike the interface with the neutron beam from both sides of a liquid-liquid interface. For example, planar lipid bilayers were prepared and
Pertinence: 2%
Pages
techniques : Aerodynamic levitation coupled with CO 2 lasers heating X-ray radiography and white beam X-ray topography imaging techniques Finite Differences and Finite Elements methods for thermodynamics
Pertinence: 21%
Pages
along lines of constant wavelength, which is the right choice if the sample is flat and the incoming beam divergence is higher than the detector resolution (incoherent method), or you can choose to add foreground ... which is the right choice if the sample is bent or the detector resolution is higher than the incoming beam divergence. In any case ...
Pertinence: 20%
Pages
kinds of scientific studies, which depends for example on the energy and flux of the incident neutron beam, polarized neutron capability and the availability of specific sample environments. IN1 TAS/LAGRANGE ... high energy resolution using the change in polarization between the incident and scattered neutron beams to measure small energy changes ...
Pertinence: 15%
Pages
on of their configuration. This version permits to simulate intensity and distribution of neutron beam in both real and momentum subspaces at different positions along the TAS beamline. vTAS A Virtual
Pertinence: 14%
Pages
Aluminium or Copper in the beam. Harmonic wavelengths in ki and kf Bragg/phonon contamination Incoherent scattering of monochromator/analyzer: A small part (10-5) of the incoming beam is always scattered i ... incoming beam. Fast neutrons that may pass the protections will give an additional peak. Also, for small A4 angles, one can have an ...
Pertinence: 28%
Pages
followed by a quartz monochromator, allows a monochromatic beam with high energy (E=17 keV, l=0.71 Å) to be obtained. Three set of slits limit the beam size to 2 mm width and 15 mm high at the sample position ... the DNA used. With higher organization comes a decrease in stability. The 3D network built by these beams can still exhibit some ...
Pertinence: 5%
