<210° +56° < χ <205° -180° < φ <180° Detector 120° x 30° position-sensitive detector detector gas: 3He (5 atm) + CF4 (1 atm) Nominal resolution for fixed sample-detector distance of 76 cm 0.19° horiz. x ... sample. The new very large banana PSD is of innovative design and works at high gas pressure (5 atm 3He + 1 atm CF 4 ) for high efficiency ...
Recherche
Recherche de 3he.
59 résultats ont été trouvés en 4 millisecondes.
Affiche les résultats de 11 à 20 sur 59.
Pages
Pertinence: 36%
Pages
9° x 0.9° Angular range 2° ... 120° Fourier time range 0.03 ... 50 ns (10 Å) 0.002 ... 3 ns (4 Å) Energy range 1.3x10 -5 ... 0.01 meV (10 Å) 2x10-4 ... 0.15 meV (4 Å) Momentum transfer range 0.03 ... 2 ... sample stage takes all ILL standard sample environments including orange cryostats, cryo-furnaces and 3He cryostats. A non-magnetic high ...
Pertinence: 17%
Pages
mode) Detectors nuclear-track position-sensitive UCN detectors spatial resolution ~1 µm low-background 3He UCN counters background ~10 -4 s -1 one- and two-dimensional UCN detectors spatial resolution of ~100 ... A monochromatic neutrons reflected towards guide H172A Ultra Cold Neutron (UCN) source Small size 4 He source 5 liters Environment setup ...
Pertinence: 18%
Pages
momentum transfer range 3·10 -3 ≤ q [nm -1 ] ≤ 6 detector type (since January 2021) 3He gas detector (256 1-m long, 8 mm outer diameter stacked tubes from Reuter-Stokes, installed in 3 panels, shaped as a ... 47.65 mm -> 46.10 mm from 4.1 to 3.1 m 46.10 mm -> 38.0 mm from 3.1 to 1.6 m guide-to-sample distances 1.6, 3.1, 4.1, 5.6, 6.7, 7.7, 10.2, ...
Pertinence: 43%
Pages
θ < 3.8˚ (horizontal) constant wavelength resolution δλ/λ [0.8-7.0%] elastic Q-range (down) 0.0045 – 0.42 Å -1 (horizontal) elastic Q-range (up) 0.0045 – 0.27 Å -1 (horizontal) Detector type 3He Tubular ... 0045 to 0.42 Å -1 can be achieved for horizontal samples by using just two incoming angles of 0.62 and 3.8˚, and the q-range can be extended ...
Pertinence: 15%
Pages
please contact the college secretary. He can schedule a seminar at the ILL any time (best on Monday and Wednesday). Travel and expenses for your stay may be reimbursed (3 per diems and travel support). Do
Pertinence: 14%
Pages
used for College 6 proposals are: Reflectometers: SuperADAM , D17 Diffractometers: D1B , D2B , D20 , D3 , D4 , XTREMED SANS spectrometers: D11 , D22 , D33 Small momentum transfer diffractometer: D16 Triple-axis ... rs: IN15 , WASP If you want to come to the ILL and give a seminar, please contact Gabriel Cuello . He can schedule a seminar at the ILL ...
Pertinence: 15%
Pages
and testing of novel therapeutic approaches to systemic amyloidosis and Alzheimer’s disease. CH3NH3PbI3 hybrid halide perovskite: beyond photovoltaics Friday, 24 March 2017, at 2:00 p.m. Chadwick amphitheatre ... Lausanne CH-1015 Lausanne laszlo.forro@ remove-this. epfl.ch Recently, it has been shown that CH3NH3PbI3 is very promising material in ...
Pertinence: 9%
Pages
A5 - AG3 Ø70 Top loading 106ILHV49 1.5 - 550 A5 - AG3 Ø49 x 112 Top loading 118ILHV49 1.5 - 550 A5 - AG3 Ø49 Dual-exchanger, top loading, compatible with Cryopad-III 119ILHV49 1.5 - 550 A5 - AG3 Ø49 Top ... loading, new cold-valve 141ILHV49 1.5 - 550 A5 - AG3 Ø49 x 110 Top loading 145ILHV70 1.5 - 550 A5 - AG3 Ø70 x 195 Top loading 155ILHV49 1.8 - ...
Pertinence: 14%
Pages
Detector: 2-dimensional 3He detector with 128 x 128 pixels of 7.5 x 7.5 mm Max. counting rate: 200 KHz Electronic noise: ca. 2 Hz on whole detector Sample-to-detector distances: 1.3 < L < 18 m Horizontal ... 12000 s -1 ) 3. Data acquisition and NOMAD The data acquisition itself is controlled by an instrument-specific version of the program NOMAD , ...