received serial line data from many of the neutron beam instruments; a polling program looked for data transfer requests from several instruments. The DEC computer had two additional DN20 front-end PDP11/34s ... task-task communications programs (Tillier, ILL80T15T). The protocol allowed use of either the instrument DEC VT11 graphic display or a ...
Recherche
Recherche de instrument.
303 résultats ont été trouvés en 6 millisecondes.
Affiche les résultats de 141 à 150 sur 303.
Pages
Pertinence: 26%
Pages
with a capacity of about 40 MB, holding data for each CARINE and NICOLE instrument appended into sequential files for each instrument. Depending on volumes of data these were copied to 800 bpi nine track ... number was associated with each measurement (NUMOR). On some instruments (e.g. D11) this was reset at the start of each year. For other instru ...
Pertinence: 27%
Pages
offered to scientists whose instruments had user documentation. There was hence an unequaled spate of production of internal technical reports describing use of instruments and software. Calcul Scientific ... and software, with issues about every two months. For the instruments, Lefèvre was assiduous in producing a technical note for each instrumen ...
Pertinence: 23%
Pages
As instruments were progressively transferred to more modern replacements and the complex environment simplified the overall reliability improved. M id 1970s - Individual PDP11 on new instruments One ... introduction of SEMS Solar16/40 individual computers for the 3-axis instruments and D1B with new electronics, and PDP11s for the other instrument ...
Pertinence: 100%
Pages
the reactor was restarted in 1995 there had been little renewal manpower or money for instruments. Most instruments were still running VAX-VMS. Data were transferred to the central cluster and converted ... in page " Main system replacement " ) Users were encouraged to take away data even when the instrumentation and data treatment packages were ...
Pertinence: 23%
Pages
and 4-circle instruments (ANDROMACHIE brought to ILL for D15/D16). The Pluto triple axis hence had its own computer, since costs were falling. A few years later at Saclay the instruments were controlled ... Barthélemy troubleshooting an instrument via the microphone. The T2000 is seen in the background ©ILL, A. Barthélemy's archives 1971- Alain ...
Pertinence: 27%
Pages
Only by using neutron instruments from across the globe, have researchers been able to characterise the magnetism of a graphene-like material. Like graphite, the compound NiPS 3 takes a structure with ... overview of the entire dispersion relation. They also measured one of these crystals using the TAIPAN instrument at ANSTO and IN8 at the ILL . ...
Pertinence: 24%
Pages
and the cylindrical tank of S22, the EDM instrument. ©1980 ILL and Neyrtec The Ultra Cold Neutron (UCN) storage bottle which was at the core of the EDM instrument. ©1980 ILL and Neyrtec Weak neutral currents ... Ultra Cold Neutron(UCN) [4] EDM results became available. Neutron magnetic moment Layout of the instrument that was installed on the H18 ...
Pertinence: 19%
Pages
PF2 Level D). Today, the areas of research and techniques he pioneered are still active and new instruments are trying to go even further. Ramsey's PhD students and collaborators at the time have excellent
Pertinence: 21%
Pages
ENSA Neutron Instrumentation and Innovation Award " in recognition of his outstanding contributions to the development of Neutron Imaging, in particular for realising the NeXT-Grenoble instrument at the ILL ... Navid Qureshi Navid is a crystallographer who was Instrument Responsible of the 4-circle diffractometer D10 from 2014 to 2017 and has been ...
Pertinence: 22%