The vessel of the cryostat is pumped dynamically and the cryostat is translated into the neutron beam when needed. A logic process controller ( Schneider M251 ) monitors the water flow rate and temperature
Recherche
Recherche de beams.
401 résultats ont été trouvés en 3 millisecondes.
Affiche les résultats de 91 à 100 sur 401.
Pages
Pertinence: 17%
Pages
of a compact and high-resolution time-of-flight measurement device for cold neutron beams." Phys. Rev. Acceler. Beams 22: 032801. P.P. Crepin, E.A. Kupryianova, R. Guerout, A. Lambrecht, V.V. Nesvizhevsky ... towards the first demonstration of gravitational quantum states of atoms with a cryogenic hydrogen beam." Europ. Phys. J. D 77:50. Petoukhov, ...
Pertinence: 11%
Pages
symmetries as well as the Yttrium and Oxygen. Experiments at the Institute Laue-Langevin (ILL) neutron beam facility in Grenoble, France have for the first time fully exposed the complex magnetic behaviour ... polarisations had never been measured. This is where the neutron studies with IN20 come in. A neutron beam of given energy is passed through ...
Pertinence: 18%
Pages
particles and nuclear physics. It has provided the strongest polarised and unpolarised cold neutron beam in the world since its conception. Yet, as technology advances, the ILL needs to constantly improve ... one to three reflections by the SM coating, only one spin component survives, making the transmitted beam highly polarised. “We have ...
Pertinence: 20%
Pages
featuring an inclined window allowing the exact position of the liqud interface relative to the neutron beam to be measured. The lid is heated to prevent condensation and Sapphire windows, also heated, close
Pertinence: 20%
Pages
guides to the eye). (c) Off-specular scattering plotted as a color map for different αi and exiting beam angles αf. Schematics of the experimental setup at Super ADAM (top) and MAGIK (bottom) with the sample
Pertinence: 20%
Pages
grown at above 700 °C onto a gadolinium gallium garnet (GGG) substrate by means of laser molecular beam epitaxy. The diffusion-assisted formation of a Ga-rich region at the YIG/GGG interface is demonstrated
Pertinence: 20%
Pages
pySAred (.h5 files reduction software) Features: Automated .h5 files processing Automated Direct Beam (.h5) selection based on the data scan name Preview panels for Reflectivity Profile, Detector Images ... 2Theta", "Qx vs. Qz") Reductions / Corrections available: -- Devision by monitor / time -- Direct beam normalization (incl. DB attenuator ...
Pertinence: 25%
Pages
of high robustness. The counting rate curve was measured on the CT2 instrument with a collimated beam of 7 mm x 7 mm. Different thicknesses of plexi attenuator were installed 2 metres upstream of the ... n of D20 (50 kHz/channel). Figure 3: counting rate measurement on the CT2 instrument. The neutron beam was 7 mm x 7 mm. The most critical part in ...
Pertinence: 18%
Pages
the weak axial-vector coupling constant in the decay of free neutrons using a pulsed cold neutron beam
Pertinence: 11%