These error codes are related with the CORBA requests and returned by all interfaces. They are defined as follows:

CodesDescription
0Operation was successful
1Instrument variable requested by MAD/NOMAD is non-existent.
2Instrument variable requested by MAD/NOMAD of bad data type.
3Instrument variable requested by MAD/NOMAD cannot be copied from handle.
4Instrument name sent by MAD/NOMAD doesn't match Igor's instrument name.
5The "NOMAD:Cryogenics" data folder does not exist.
6Cannot get the LN2 level (Igor variable does not exist).
7Cannot get the LN2 level (Igor variable of bad data type).
8Cannot get the LN2 level (Igor data/time variable does not exist).
9Cannot get the LN2 level (Igor date/time variable of bad data type).
10Cannot get the LHe level (Igor variable does not exist).
11Cannot get the LHe level (Igor variable of bad data type).
12Cannot get the LHe level (Igor data/time variable does not exist).
13Cannot get the LHe level (Igor date/time variable of bad data type).
14Cannot get the cold-valve mode (Igor variable does not exist).
15Cannot get the cold-valve mode (Igor variable of bad data type).
16Cannot get the cold-valve mode (Igor data/time variable does not exist).
17Cannot get the cold-valve mode (Igor date/time variable of bad data type).
18Cannot get the cold-valve pressure (Igor variable does not exist).
19Cannot get the cold-valve pressure (Igor variable of bad data type).
20Cannot get the cold-valve pressure (Igor data/time variable does not exist).
21Cannot get the cold-valve pressure (Igor date/time variable of bad data type).
22Cannot get the cold-valve power (Igor variable does not exist).
23Cannot get the cold-valve power (Igor variable of bad data type).
24Cannot get the cold-valve power (Igor data/time variable does not exist).
25Cannot get the cold-valve power (Igor date/time variable of bad data type).
26Cannot get the cold-valve status code (Igor variable does not exist).
27Cannot get the cold-valve status code (Igor variable of bad data type).
28Cannot get the cold-valve status message (Igor variable does not exist).
29Cannot get the cold-valve status message (cannot get string from handle).
30Cannot get the cold-valve status message (Igor variable of bad data type).
31The "NOMAD:MagneticField" data folder does not exist.
32Cannot get the magnetic field (Igor variable does not exist).
33Cannot get the magnetic field (Igor variable of bad data type).
34Cannot get the magnetic field (Igor date/time variable does not exist).
35Cannot get the magnetic field (Igor date/time variable of bad data type).
36Cannot get the magnetic field setpoint (Igor variable does not exist).
37Cannot get the magnetic field setpoint (Igor variable of bad data type).
38Cannot get the magnetic field setpoint (Igor date/time variable does not exist).
39Cannot get the magnetic field setpoint (Igor date/time variable of bad data type).
40Cannot get the cryomagnet persistent mode (Igor variable does not exist).
41Cannot get the cryomagnet persistent mode (Igor variable of bad data type).
42Cannot get the cryomagnet persistent mode (Igor date/time variable does not exist).
43Cannot get the cryomagnet persistent mode (Igor date/time variable of bad data type).
44Cannot get/set the magnetic field Tolerance (Igor variable does not exist).
45Cannot get the magnetic field Tolerance (Igor variable of bad data type).
46Cannot get/set the magnetic field Tolerance (Igor date/time variable does not exist).
47Cannot get the magnetic field Tolerance (Igor date/time variable of bad data type).
48Cannot determine if the sample is at the expected field (Igor variable does not exist).
49Cannot determine if the sample is at the expected field (Igor variable of bad data type).
50Cannot determine if the sample is at the expected field (Igor date/time variable does not exist).
51Cannot determine if the sample is at the expected field (Igor date/time variable of bad data type).
52Cannot get the magnet status code (Igor variable does not exist).
53Cannot get the magnet status code (Igor variable of bad data type).
54Cannot get the magnet status message (Igor variable does not exist).
55Cannot get the magnet status message (cannot get string from handle).
56Cannot get the magnet status message (Igor variable of bad data type).
57Cannot get/set the magnetic field interface timeout (Igor variable does not exist).
58Cannot get the magnetic field interface timeout (Igor variable of bad data type).
59Cannot get/set the magnetic field interface timeout (Igor date/time variable does not exist).
60Cannot get the magnetic field interface timeout (Igor date/time variable of bad data type).
61Cannot get the magnetic field status code (Igor variable does not exist).
62Cannot get the magnetic field status code (Igor variable of bad data type).
63Cannot get the magnetic field status message (Igor variable does not exist).
64Cannot get the magnetic field status message (cannot get string from handle).
65Cannot get the magnetic field status message (Igor variable of bad data type).
66The "NOMAD:Pressure" data folder does not exist.
67Cannot get the regulation pressure (Igor variable does not exist).
68Cannot get the regulation pressure (Igor variable of bad data type).
69Cannot get the regulation pressure (Igor date/time variable does not exist).
70Cannot get the regulation pressure (Igor date/time variable of bad data type).
71Cannot get the pressure setpoint (Igor variable does not exist).
72Cannot get the pressure setpoint (Igor variable of bad data type).
73Cannot get the pressure setpoint (Igor date/time variable does not exist).
74Cannot get the pressure setpoint (Igor date/time variable of bad data type).
75Cannot get the sample pressure (Igor variable does not exist).
76Cannot get the sample pressure (Igor variable of bad data type).
77Cannot get the sample pressure (Igor date/time variable does not exist).
78Cannot get the sample pressure (Igor date/time variable of bad data type).
79Cannot get/set the pressure tolerance (Igor variable does not exist).
80Cannot get the pressure tolerance (Igor variable of bad data type).
81Cannot get/set the pressure tolerance (Igor date/time variable does not exist).
82Cannot get the pressure tolerance (Igor date/time variable of bad data type).
83Cannot determine if the sample is at the expected pressure (Igor variable does not exist).
84Cannot determine if the sample is at the expected pressure (Igor variable of bad data type).
85Cannot determine if the sample is at the expected pressure (Igor date/time variable does not exist).
86Cannot determine if the sample is at the expected pressure (Igor date/time variable of bad data type).
87Cannot get the press status code (Igor variable does not exist).
88Cannot get the press status code (Igor variable of bad data type).
89Cannot get the press status message (Igor variable does not exist).
90Cannot get the press status message (cannot get string from handle).
91Cannot get the press status message (Igor variable of bad data type).
92Cannot get/set the presure interface timeout (Igor variable does not exist).
93Cannot get the pressure interface timeout (Igor variable of bad data type).
94Cannot get/set the pressure interface timeout (Igor date/time variable does not exist).
95Cannot get the pressure interface timeout (Igor date/time variable of bad data type).
96Cannot get the pressure error code (Igor variable does not exist).
97Cannot get the pressure error code (Igor variable of bad data type).
98Cannot get the pressure error message (Igor variable does not exist).
99Cannot get the pressure error message (cannot get string from handle).
100Cannot get the pressure error message (Igor variable of bad data type).
101The "NOMAD:Temperature" data folder does not exist.
102Cannot get the regulation temperature (Igor variable does not exist).
103Cannot get the regulation temperature (Igor variable of bad data type).
104Cannot get the regulation temperature (Igor date/time variable does not exist).
105Cannot get the regulation temperature (Igor date/time variable of bad data type).
106Cannot get the temperature setpoint (Igor variable does not exist).
107Cannot get the temperature setpoint (Igor variable of bad data type).
108Cannot get the temperature setpoint (Igor date/time variable does not exist).
109Cannot get the temperature setpoint (Igor date/time variable of bad data type).
110Cannot get the sample temperature #1 (Igor variable does not exist).
111Cannot get the sample temperature #1 (Igor variable of bad data type).
112Cannot get the sample temperature #1 (Igor date/time variable does not exist).
113Cannot get the sample temperature #1 (Igor date/time variable of bad data type).
114Cannot get the sample temperature #2 (Igor variable does not exist).
115Cannot get the sample temperature #2 (Igor variable of bad data type).
116Cannot get the sample temperature #2 (Igor date/time variable does not exist).
117Cannot get the sample temperature #2 (Igor date/time variable of bad data type).
118Cannot get/set the temperature tolerance (Igor variable does not exist).
119Cannot get the temperature tolerance (Igor variable of bad data type).
120Cannot get/set the temperature tolerance (Igor date/time variable does not exist).
121Cannot get the temperature tolerance (Igor date/time variable of bad data type).
122Cannot determine if the sample is at the resquested temperature (Igor variable does not exist).
123Cannot determine if the sample is at the resquested temperature (Igor variable of bad data type).
124Cannot determine if the sample is at the resquested temperature (Igor date/time variable does not exist).
125Cannot determine if the sample is at the resquested temperature (Igor date/time variable of bad data type).
126Cannot get the equipment status code (Igor variable does not exist).
127Cannot get the equipment status code (Igor variable of bad data type).
128Cannot get the equipment status message (Igor variable does not exist).
129Cannot get the equipment status message (cannot get string from handle).
130Cannot get the equipment status message (Igor variable of bad data type).
131Cannot get/set the temperature interface timeout (Igor variable does not exist).
132Cannot get the temperature interface timeout (Igor variable of bad data type).
133Cannot get/set the temperature interface timeout (Igor date/time variable does not exist).
134Cannot get the temperature interface timeout (Igor date/time variable of bad data type).
135Cannot get the temperature error code (Igor variable does not exist).
136Cannot get the temperature error code (Igor variable of bad data type).
137Cannot get the temperature error message (Igor variable does not exist).
138Cannot get the temperature error message (cannot get string from handle).
139Cannot get the temperature error message (Igor variable of bad data type).